RPS Datasheet

PORTABLE HIGH PRESSURE POWER PACK type RPS

TECHNICAL SPECIFICATIONS

AIR Consumption Connection Maximum pressure Air* Filtering degree Air quality standard

max. 3 Nm3/min ½” BSP female 7 bar Dry and filtered air. No lubrication 20 micron ISO 8573-1 Class 2.3.2

HIGH PRESSURE CONNECTIONS Outlet connection Transmitter connection (F1: P160 - 10/20/30 & P200 - 30) (F2: P160 - 40+ & P200 - 45+)

FU2 (3/4” - 16 UNF HP-female; for 3/8” or 10 mm HP tubing) F1 (M16x1.5 HP-Female; for 1/4” or 6 mm HP tubing) F2 (M20x1.5 HP-Female; for 3/8” or 10 mm HP tubing)

MEDIUM Connection Type**

½” BSP female Water Oil Emulsion of water and oil

Cleanliness Viscosity Temperature

ISO 4406 - 14/9 1,10 - 3 to 1 Pa.s -10 - 60 °C

* The pump has a lifetime lubrication. Once lubricated air is used lubrication will be needed for the lifetime of the unit. ** For any other media please contact Resato for advice.